Consensus guideline

Dose-Volume Histogram Compendium of Dose Constraints for Treatment Planning: An ASTRO Consensus Paper

Puckett LL, Apisarnthanarax S, Ballas LK, et al. · ASTRO / Veterans Affairs

View Source Source Verified

DoseLab summary

Consensus DVH planning goals for breast, head and neck, liver, lung, prostate and rectal cancer, built from VA/ASTRO quality-measure work and approved by modified Delphi vote. Tables are also published as Appendix E3 on astro.org. DoseLab's prostate 70 Gy / 28 fx column quotes Table 21.

Why this is useful

ASTRO and the VA's consensus DVH goals for common schedules by site, with primary and secondary goals and the references behind each organ.

Reference details

Title
Dose-Volume Histogram Compendium of Dose Constraints for Treatment Planning: An ASTRO Consensus Paper
Authors / organization
Puckett LL, Apisarnthanarax S, Ballas LK, et al. · ASTRO / Veterans Affairs
Publication / protocol
Pract Radiat Oncol. 2026;16(3):294–317
Version
Pending verification
Year
2026
DOI
10.1016/j.prro.2025.11.003
Disease sites
Prostate, Breast, Lung, Head & Neck, GI
Topics
Dose Constraints, Plan Evaluation, Prostate, Moderate hypofractionation, ASTRO
Fractionation context
Common conventional, moderately hypofractionated and ultrahypofractionated schedules
Last reviewed by DoseLab
2026-10-14