Consensus guideline

Dose–Volume Constraints fOr oRganS At risk In Radiotherapy (CORSAIR): An “All-in-One” Multicenter–Multidisciplinary Practical Summary

Bisello S, Cilla S, Benini A, et al.

View Source Source Verified

DoseLab summary

An open-access multicenter summary of organ-at-risk dose–volume constraints for adults (Table 1) and contouring definitions based on the Global Harmonization Group nomenclature (Table 2). DoseLab uses its large bowel row where eviQ gives no number.

Why this is useful

A single open-access table of constraints for most organs, with columns for conventional fractionation and for 1, 3, 5 and 8 fractions, each footnoted to its source — plus a companion table of contouring definitions.

Reference details

Title
Dose–Volume Constraints fOr oRganS At risk In Radiotherapy (CORSAIR): An “All-in-One” Multicenter–Multidisciplinary Practical Summary
Authors / organization
Bisello S, Cilla S, Benini A, et al.
Publication / protocol
Curr Oncol. 2022;29(10):7021–7050
Version
Pending verification
Year
2022
DOI
10.3390/curroncol29100552
Disease sites
Lung, Prostate, GI, GYN, Head & Neck, CNS / Brain, Breast
Topics
Dose Constraints, Contouring, SBRT, Conventional fractionation
Fractionation context
Conventional; SBRT at 1, 3, 5 and 8 fractions