AAPM report

The management of respiratory motion in radiation oncology: report of AAPM Task Group 76

Keall PJ, Mageras GS, Balter JM, et al. · AAPM

View Source Source Verified

DoseLab summary

AAPM task group report on respiratory motion in thoracic, abdominal and pelvic treatment. It groups management approaches into motion-encompassing methods, respiratory gating, breath-hold techniques, forced shallow breathing (such as abdominal compression) and respiration-synchronized (tracking) techniques. Read in the AAPM report PDF (Report No. 91, July 2006): using ICRU Report 62 nomenclature, the PTV adds margins to the CTV for respiratory (intrafraction) motion, interfraction motion and set-up error; without a respiratory management device the entire range of motion should be considered in the internal margin; and for lung tumors a maximum intensity projection (MIP) can give the motion-encompassing volume, provided there is no mediastinal involvement.

Why this is useful

The standard starting point for respiratory motion management: how motion is measured, and the main approaches to handling it.

Reference details

Title
The management of respiratory motion in radiation oncology: report of AAPM Task Group 76
Authors / organization
Keall PJ, Mageras GS, Balter JM, et al. · AAPM
Publication / protocol
Med Phys. 2006;33(10):3874–3900
Version
Pending verification
Year
2006
DOI
10.1118/1.2349696
Disease sites
Lung, GI, Breast
Topics
Motion, 4DCT, Gating, Breath hold, AAPM, ITV
Fractionation context
Pending verification
Last reviewed by DoseLab
2026-10-06

Cited on DoseLab